... chambers in this instance is cooled by passing over sets of direct expansion Baudelot coils , located in a compartment below the spray chamber and which are operated only at times when needed . The original installation consisted of two ...
... chambers in this instance is cooled by passing over sets of direct expansion Baudelot coils , located in a compartment below the spray chamber and which are operated only at times when needed . The original installation consisted of two ...
Stran 19
... chamber which surrounds the smoke flue and which is built in the stack , is heated to a temperature suit- able for drying various kinds of ma- terial . The source of heat is a bank of four ww w 0:97 + Drying Compartments . Detail of ...
... chamber which surrounds the smoke flue and which is built in the stack , is heated to a temperature suit- able for drying various kinds of ma- terial . The source of heat is a bank of four ww w 0:97 + Drying Compartments . Detail of ...
Stran 21
... chamber ex- tending from the bottom of stack to within 2 ft . of the top . This chamber is divided into two parts by a baffle so that outside air , which enters at the bottom , travels up one side and down the other and is drawn out at ...
... chamber ex- tending from the bottom of stack to within 2 ft . of the top . This chamber is divided into two parts by a baffle so that outside air , which enters at the bottom , travels up one side and down the other and is drawn out at ...
Stran 22
... chamber is again ready for refilling at the lower pressure . These traps have four connections , the inlet for condensation , the outlet for condensation , the high pressure steam inlet , and the vent pipe for the relief of the pressure ...
... chamber is again ready for refilling at the lower pressure . These traps have four connections , the inlet for condensation , the outlet for condensation , the high pressure steam inlet , and the vent pipe for the relief of the pressure ...
Stran 24
... Chamber Steam Pipe from Boiler To Feed Water Heater Steem Header To Boiler Starting Volve Receiver FIG . 6. - HOLLY SYSTEM . Separator On the other hand if the receiver is to take care of the condensation from several different ...
... Chamber Steam Pipe from Boiler To Feed Water Heater Steem Header To Boiler Starting Volve Receiver FIG . 6. - HOLLY SYSTEM . Separator On the other hand if the receiver is to take care of the condensation from several different ...
Druge izdaje - Prikaži vse
Pogosti izrazi in povedi
air supply ammonia amount anemometer apparatus ARMAGNAC bituminous coal boiler building Camp Upton chamber Chicago chimney City coils combustion committee Company condensation connection construction cooling Cooperstown cost cubic foot Daily Range damper designed Detroit District Heating draft drying ducts dust efficiency electric equipment evaporation factor fire floor flue friction fuel furnace gases grate heater Heating and Ventilating heating engineers heating plant heating system hot water hour humidifying humidity inlet installed Kewanee loss manufacturers meeting ment meter method moisture operation perature pipe Pitot tube power plant pressure pump radiator refrigeration risers shows smoke smoke pipe smokeless Sn Sn square foot stack steam heating steam main supply surface tank temperature tests thermostat tion trap tubes vacuum valve velocity VENTILATING MAGAZINE Vernon Hill wall water heating weather York
Priljubljeni odlomki
Stran 62 - DRAMA, and that the following is, to the best of his knowledge and belief, a true statement of the ownership, management (and if a daily paper, the circulation), etc., of the aforesaid publication for the date shown in the above caption, required by the Act...
Stran 43 - ... as to render harmless, so far as is practicable, all the gases, vapors, dust, or other impurities generated in the course of the manufacturing process or handicraft carried on therein that may be injurious to health.
Stran 41 - ... are not surrounded with proper safeguards for preventing accidents or Injury to those employed at or near them, he shall notify In writing the owner, proprietor or agent of such workshops or factories to make, within thirty days, the alterations or additions by him deemed necessary for the safety and protection of the employees...
Stran 41 - ... when the same is open or in operation, for the purpose of gathering facts and statistics such as are contemplated by this act, and to examine into the methods of protection from danger to employes and the sanitary conditions in and around such buildings and places and make a record thereof...
Stran 42 - ... article, and to which or over which premises, room, or place, the employer of the persons working therein has the right of access or control...
Stran 62 - That the owners are: (Give names and addresses of individual owners, or, if a corporation, give its name and the names and addresses of stockholders owning or holding 1 per cent or more of the total amount of stock.) The National Historical Society.
Stran 42 - ... a majority of the persons therein employed are members of such family, shall not of itself constitute such house or room a workshop within this definition.
Stran 58 - accident' as used in the phrases 'personal injuries due to accident' or 'injuries or death caused by accident' in this act shall, unless a different meaning is clearly indicated by the context, be construed to mean an unexpected or unforeseen event, happening suddenly and violently, with or without human fault and producing at the time, injury to the physical structure of the body.
Stran 64 - None 2. That the owners are: (Give names and addresses of individual owners, or if a corporation, give its name and the names and addresses of stockholders owning or holding ] per cent or more of the total amount of stock.) Department of Education, San Juan, Porto Rico.
Stran 43 - The owner, agent or lessee of a factory shall provide, in each workroom thereof, proper and sufficient means of ventilation, and shall maintain proper and sufficient ventilation; if...